Udvidet returret til d. 31. januar 2025

Air-Cooled Condenser Operation under Varying Ambient Conditions

Bag om Air-Cooled Condenser Operation under Varying Ambient Conditions

Scientific Study from the year 2024 in the subject Physics - Thermodynamics, language: English, abstract: The objective of this report is to make up for the following deficiencies at least on a general level - while still using first principles. Air-cooled condensers are widely used at the cold end of thermal power cycles. With this equipment cooling water required in wet cooled power plants may be saved on a large scale. To operate fans which convey dry cooling air to the condenser modules electric power is required which reduces overall power plant effectiveness. Consequently, pumping power consumption should be as small as possible. During operation it is therefore common to reduce fan power consumption by switching down or off fans of individual modules or, in some case complete ACC streets if ambient conditions and operation parameters are promising. Performance guarantees are normally specified with all equipment in full action. Only primary variable variations such as ambient temperature, ambient air pressure or total steam flow rate for a reduced range at fan full speed are part of the performance guarantee. Therefore, effects of fan switch or high cross-wind levels remain open issues.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9783963562136
  • Indbinding:
  • Paperback
  • Udgivet:
  • 21. februar 2024
  • Størrelse:
  • 148x210x3 mm.
  • Vægt:
  • 68 g.
  • BLACK WEEK
Leveringstid: 2-3 uger
Forventet levering: 13. december 2024

Beskrivelse af Air-Cooled Condenser Operation under Varying Ambient Conditions

Scientific Study from the year 2024 in the subject Physics - Thermodynamics, language: English, abstract: The objective of this report is to make up for the following deficiencies at least on a general level - while still using first principles. Air-cooled condensers are widely used at the cold end of thermal power cycles. With this equipment cooling water required in wet cooled power plants may be saved on a large scale. To operate fans which convey dry cooling air to the condenser modules electric power is required which reduces overall power plant effectiveness. Consequently, pumping power consumption should be as small as possible. During operation it is therefore common to reduce fan power consumption by switching down or off fans of individual modules or, in some case complete ACC streets if ambient conditions and operation parameters are promising. Performance guarantees are normally specified with all equipment in full action. Only primary variable variations such as ambient temperature, ambient air pressure or total steam flow rate for a reduced range at fan full speed are part of the performance guarantee. Therefore, effects of fan switch or high cross-wind levels remain open issues.

Brugerbedømmelser af Air-Cooled Condenser Operation under Varying Ambient Conditions



Find lignende bøger
Bogen Air-Cooled Condenser Operation under Varying Ambient Conditions findes i følgende kategorier:

Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.