Udvidet returret til d. 31. januar 2025

Development of Conductng Polymer Based Nucleic Acid Biosensors

Bag om Development of Conductng Polymer Based Nucleic Acid Biosensors

Nucleic acid biosensors have been found to have interesting possibilities for applications in various fields including environmental and medical screening. The two types of analysis used for the nucleic acid biosensors are : (a) detection of genotoxicants/ DNA damage (b) detection of DNA hybridization. For the detection of genotoxicants, the double stranded calf thymus DNA has been electrochemically entrapped into conducting polymers like Polypyrrole (PPy) and Polyaniline (PANI) films to detect chlorpyrifos and malathion. Compared to DNA-PPy, DNA-PANI electrodes have better detection limit for chlorpyrifos and malathion (0.5 ppb and 0.01 ppm, respectively) within 30s, and are stable for about 6 months. The PNA and DNA probes specific to M. tuberculosis have been immobilized onto the PPy and PANI films prepared onto ITO glass for detection of complementary target. The obtained detection limit is about 0.1attomole within 30s and electrodes could detect the genomic DNA of M. tuberculosis in serum samples up to 2.5 pg/¿l within about 60s at 300 C and can be used 8¿9 times.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9783838380513
  • Indbinding:
  • Paperback
  • Sideantal:
  • 196
  • Udgivet:
  • 8. juli 2010
  • Størrelse:
  • 152x229x11 mm.
  • Vægt:
  • 295 g.
  • BLACK NOVEMBER
Leveringstid: 2-3 uger
Forventet levering: 2. december 2024

Beskrivelse af Development of Conductng Polymer Based Nucleic Acid Biosensors

Nucleic acid biosensors have been found to have interesting possibilities for applications in various fields including environmental and medical screening. The two types of analysis used for the nucleic acid biosensors are : (a) detection of genotoxicants/ DNA damage (b) detection of DNA hybridization. For the detection of genotoxicants, the double stranded calf thymus DNA has been electrochemically entrapped into conducting polymers like Polypyrrole (PPy) and Polyaniline (PANI) films to detect chlorpyrifos and malathion. Compared to DNA-PPy, DNA-PANI electrodes have better detection limit for chlorpyrifos and malathion (0.5 ppb and 0.01 ppm, respectively) within 30s, and are stable for about 6 months. The PNA and DNA probes specific to M. tuberculosis have been immobilized onto the PPy and PANI films prepared onto ITO glass for detection of complementary target. The obtained detection limit is about 0.1attomole within 30s and electrodes could detect the genomic DNA of M. tuberculosis in serum samples up to 2.5 pg/¿l within about 60s at 300 C and can be used 8¿9 times.

Brugerbedømmelser af Development of Conductng Polymer Based Nucleic Acid Biosensors



Find lignende bøger
Bogen Development of Conductng Polymer Based Nucleic Acid Biosensors findes i følgende kategorier:

Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.