Udvidet returret til d. 31. januar 2025

Development and Analysis of Solar Milk Pasteurization System

Bag om Development and Analysis of Solar Milk Pasteurization System

The main aim of this research work is to test and evaluate the performance of solar milk pasteurization system. To evaluate the performance of solar milk pasteurization system, solar hot water system, concentric tube type heat exchanger, cooling tank has used. To test the solar milk pasteurization system, three different mass flow rate of hot water like 2 liter/minute, 3 liter/minute and 5 liter/minute and cold milk 0.5 litre/minute, 0.7 litre/minute and 1.0 litre/minute have been used. After the pasteurization, the obtained milk from the concentric tube type heat exchanger has been tested in laboratory and obtained satisfactory results. From the series of experiments, it has been found that, the hot water flow rate of 5 litre/minute and milk flow rate of 0.5 litre/minute found optimum for the pasteurization system. All the results of effect of flow rate on heat transfer from hot water, cold water, Logarithmic mean temperature difference, Overall heat transfer coefficient of inner and outer surface area and effectiveness also determined and compared with other researchers work and found good agreement with the results.

Vis mere
  • Sprog:
  • Engelsk
  • ISBN:
  • 9783659427565
  • Indbinding:
  • Paperback
  • Sideantal:
  • 80
  • Udgivet:
  • 6. september 2019
  • Størrelse:
  • 152x229x5 mm.
  • Vægt:
  • 127 g.
  • BLACK NOVEMBER
Leveringstid: 2-4 uger
Forventet levering: 18. december 2024

Beskrivelse af Development and Analysis of Solar Milk Pasteurization System

The main aim of this research work is to test and evaluate the performance of solar milk pasteurization system. To evaluate the performance of solar milk pasteurization system, solar hot water system, concentric tube type heat exchanger, cooling tank has used. To test the solar milk pasteurization system, three different mass flow rate of hot water like 2 liter/minute, 3 liter/minute and 5 liter/minute and cold milk 0.5 litre/minute, 0.7 litre/minute and 1.0 litre/minute have been used. After the pasteurization, the obtained milk from the concentric tube type heat exchanger has been tested in laboratory and obtained satisfactory results. From the series of experiments, it has been found that, the hot water flow rate of 5 litre/minute and milk flow rate of 0.5 litre/minute found optimum for the pasteurization system. All the results of effect of flow rate on heat transfer from hot water, cold water, Logarithmic mean temperature difference, Overall heat transfer coefficient of inner and outer surface area and effectiveness also determined and compared with other researchers work and found good agreement with the results.

Brugerbedømmelser af Development and Analysis of Solar Milk Pasteurization System



Gør som tusindvis af andre bogelskere

Tilmeld dig nyhedsbrevet og få gode tilbud og inspiration til din næste læsning.